MystoreMystore is an ONDC network-connected ecosystem built in India for Indian sellers. Mystore is the first ONDC network participant to connect as a Buyer and Seller NP.  You can register as a seller on Mystore and upload your catalogue. You will have a dedicated Seller page (digi-catalog) along with a Unique QR Code for your page that you can market to your buyers. Your catalogue will also appear on the ONDC network through the Mystore Buyer App and other buyer apps catering to related product domains. Mystore provides a comprehensive seller dashboard to manage your products, orders, and payouts. Mystore also facilitates seamless online shopping across categories with its Mystore Buyer App.https://www.mystore.in/s/62ea2c599d1398fa16dbae0a/66defda954ce55002beebf8c/mystore-logo-480x480.png
9th Floor, Tower A, Spaze iTech Park, Sector 49122018Gurgaon DivisionIN
Mystore
9th Floor, Tower A, Spaze iTech Park, Sector 49Gurgaon Division, IN
+918010412412https://www.mystore.in/s/62ea2c599d1398fa16dbae0a/66defda954ce55002beebf8c/mystore-logo-480x480.png"[email protected]
67694daf5cc1ee941f50381aHemocue HB 201 Microcuvettes (200 Count)Hemocue HB 201 Microcuvettes (200 Count)

PRODUCT DETAILS


Description:

The HemoCue Hb 201 Analyser H6 System is a portable and easy-to-use device that measures hemoglobin (Hb) levels in whole blood. It is commonly used in clinical settings, such as hospitals and clinics, as well as in point-of-care testing (POCT) settings, such as doctors' offices and pharmacies.The Hb 201 analyser uses microcuvettes, which are small tubes that contain a dried reagent. When a blood sample is added to the microcuvette, the reagent reacts with the hemoglobin in the blood to produce a color change. The intensity of the color change is then measured by the analyser and converted into a hemoglobin reading.The Hb 201 analyser is a very accurate and reliable device for measuring hemoglobin levels. It is also very fast, with results available in just a few seconds. This makes it an ideal tool for screening for anemia and other blood disorders.


Specifications:



  • Measurement principle: Modified azidemethemoglobin reaction

  • Wavelength: 570 nm and 880 nm

  • Measurement range: 0-25.6 g/dL (0-256 g/L, 0-15.9 mmol/L)

  • Accuracy: ±0.2 g/dL (0-25.6 g/dL)

  • Precision: CV < 2%

  • Sample volume: 10 microliters

  • Time to result: < 60 seconds

  • Operating temperature: 17-32°C (62-90°F)

  • Storage temperature: 0-50°C (32-122°F)

  • Dimensions: 6.70x3.66x1.97 in (170x93x50 mm)

  • Weight: 0.77 lbs. (350 g), with batteries installed

  • Power supply: AC adapter or 4 AA batteries


How to use:



  1. Wash your hands thoroughly with soap and water.

  2. Put on gloves.

  3. Clean the patient's finger with an alcohol swab and allow it to dry.

  4. Use a lancet to prick the side of the fingertip.

  5. Wipe away the first drop of blood with a gauze pad.

  6. Gently squeeze the fingertip to produce a small drop of blood.

  7. Touch the drop of blood to the tip of the microcuvette.

  8. Fill the microcuvette until the blood reaches the fill line.

  9. Wipe away any excess blood from the outside of the microcuvette.

  10. Insert the microcuvette into the analyser.

  11. Press the start button.

  12. The analyser will display the hemoglobin reading in a few seconds.

  13. Dispose of the microcuvette and gloves properly.


Tips for accurate readings:



  • Make sure that the microcuvette is filled completely with blood.

  • Avoid getting any bubbles into the microcuvette.

  • Do not touch the optical window of the microcuvette.

  • Clean the analyser regularly with a damp cloth.

  • Store the analyser in a cool, dry place.


MS-FPTKN4ZVT
INR7650In Stock
11

Hemocue HB 201 Microcuvettes (200 Count)

200 piece
₹7,650

MRP ₹12,000

36% OFF

Country of originIndia
Common nameHB201
Net Quantity200 piece
Manufacturer or packer nameAmbitross Pvt Ltd
Manufacturer or packer addressIN
Manufacturing Date2024
contact details consumer careAMBITROSS PRIVATE LIMITED, [email protected], +919599499570

PRODUCT DETAILS


Description:

The HemoCue Hb 201 Analyser H6 System is a portable and easy-to-use device that measures hemoglobin (Hb) levels in whole blood. It is commonly used in clinical settings, such as hospitals and clinics, as well as in point-of-care testing (POCT) settings, such as doctors' offices and pharmacies.The Hb 201 analyser uses microcuvettes, which are small tubes that contain a dried reagent. When a blood sample is added to the microcuvette, the reagent reacts with the hemoglobin in the blood to produce a color change. The intensity of the color change is then measured by the analyser and converted into a hemoglobin reading.The Hb 201 analyser is a very accurate and reliable device for measuring hemoglobin levels. It is also very fast, with results available in just a few seconds. This makes it an ideal tool for screening for anemia and other blood disorders.


Specifications:



  • Measurement principle: Modified azidemethemoglobin reaction

  • Wavelength: 570 nm and 880 nm

  • Measurement range: 0-25.6 g/dL (0-256 g/L, 0-15.9 mmol/L)

  • Accuracy: ±0.2 g/dL (0-25.6 g/dL)

  • Precision: CV < 2%

  • Sample volume: 10 microliters

  • Time to result: < 60 seconds

  • Operating temperature: 17-32°C (62-90°F)

  • Storage temperature: 0-50°C (32-122°F)

  • Dimensions: 6.70x3.66x1.97 in (170x93x50 mm)

  • Weight: 0.77 lbs. (350 g), with batteries installed

  • Power supply: AC adapter or 4 AA batteries


How to use:



  1. Wash your hands thoroughly with soap and water.

  2. Put on gloves.

  3. Clean the patient's finger with an alcohol swab and allow it to dry.

  4. Use a lancet to prick the side of the fingertip.

  5. Wipe away the first drop of blood with a gauze pad.

  6. Gently squeeze the fingertip to produce a small drop of blood.

  7. Touch the drop of blood to the tip of the microcuvette.

  8. Fill the microcuvette until the blood reaches the fill line.

  9. Wipe away any excess blood from the outside of the microcuvette.

  10. Insert the microcuvette into the analyser.

  11. Press the start button.

  12. The analyser will display the hemoglobin reading in a few seconds.

  13. Dispose of the microcuvette and gloves properly.


Tips for accurate readings:



  • Make sure that the microcuvette is filled completely with blood.

  • Avoid getting any bubbles into the microcuvette.

  • Do not touch the optical window of the microcuvette.

  • Clean the analyser regularly with a damp cloth.

  • Store the analyser in a cool, dry place.


AMBITROSS PRIVATE LIMITED

Sold By

AMBITROSS PRIVATE LIMITED

Not Cancellable
Not Returnable